Model isolar-smx-ii-3.6kw isolar-smx-ii-5.6kw
1. AC mode
Rated input voltage: 220/230vac
Input voltage range: (170vac~280vac) ± 2%; (90Vac-280Vac)±2%
Frequency: 50hz/ 60Hz (automatic detection)
Frequency range: 47 ± 0.3hz ~ 55 ± 0.3hz (50Hz) /57 ± 0.3hz ~ 65 ± 0.3hz (60Hz);
Overload / short circuit protection: circuit breaker
Efficiency: >95%
Switching time (bypass and inverter): 10ms (typical)
AC reverse protection: available
Maximum bypass overload current: 30A (3.6kw) 40A (5.6kw)
2. Inverter mode
Output voltage waveform: pure sine wave
Rated output power (VA): 3600 (3.6kw) 5600 (5.6kw)
Rated output power (W): 3600 (3.6kw) 5600 (5.6kw)
Power factor:
Rated output voltage (VAC): 230VAC (3.6kw)
230VAC (200/208/220/240vac can be set) (5.6kw)
Output voltage error: ± 5%
Output frequency range (Hz):50hz ± 0.3hz/60hz ± 0.3hz
Efficiency: >92%3600 (3.6kw) >90% (5.6kw)
Peak power: 6000va (3.6kw) 10000va (5.6kw)
Load motor capacity: 2HP (3.6kw) 4HP (5.6kw)
Output short circuit protection: circuit breaker
Specification of bypass circuit breaker: 30A (3.6kw) 40A (5.6kw)
Rated battery input voltage: 24V (minimum starting voltage 22V) (3.6kw) 48V (minimum starting voltage 44V) (5.6kw)
Battery voltage range: 20.0vdc~33vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage overvoltage alarm / overvoltage recovery… Can be set on the LCD)
Power saving mode: load ≤ 50W
3. AC charging
Battery type: lead acid or lithium battery
Maximum charging current: 80A 60A (5.6kw)
Charging voltage range: 20.0vdc~33vdc (3.6kw) 40~60vdc (5.6kw)
Short circuit protection: circuit breakers and blown fuses
Circuit breaker specification: 30A (3.6kw) 40A (5.6kw)
Overcharge protection: alarm and turn off charging after 1 minute
4. Photovoltaic charging
Maximum photovoltaic open circuit voltage: 500VDC
PV operating voltage range: 120-500vdc
MPPT voltage range: 120-450vdc
Battery voltage range: 20-33vdc 40-60vdc (5.6kw)
Maximum input power: 4000W (3.6kw) 6000W (5.6kw)
PV charging current range (settable): 0-80a
Charging short circuit protection: trip
Wiring protection: reverse wiring protection
5. Certified specifications
authentication
CE(IEC 62109-1)
EMC certification level
EN61000, C2
Operating temperature range
-15°C to 55°C
Storage temperature range
-25°C ~ 60°C
Humidity range
5% to 95% (three proofing paint protection)
noise
≤60dB
dissipate heat
Forced air cooling, fan speed change
communication interface
Usb/can/rs485 (wifi/gprs) / dry node control
Dimension (l*w*d)
378mm*280mm*103mm
426mm*322mm*126mm
Reviews